Introducing the High-Efficiency Model of the New Cooling Only Series
Saves More Energy and Delivers Exceptional Performance
User Benefit

New Casing
New reinforced design
The frame structure has been strengthened to improve resistance to earthquakes and wind while protecting against falling damage.
Strongly resists earthquakes and high winds
intensity earthquakes※1
National Institute of Technology and Evaluation (NITE), an independent Japanese administrative institution
• The magnitude of an earthquake depends not only on its intensity but also on its gal (acceleration) and natural period. Please inspect the outdoor unit after an earthquake occurs.
Energy Savings
Further energy savings have been achieved through the evolution of software and hardware technologies.
Improves Energy Efficiency Ratio (EER)
New VRV 6 X series improves energy efficiency during actual operation (low load), equipped with a new compressor, new heat exchanger and VRT Smart II control.
Hardware technology
Hardware technology
High Efficiency Compressor
New technologies increase seasonal efficiency and enable a compact design
Software technology
VRT Smart II Control
Optimal supply exactly meets the required capacity of indoor units
Further improvement of energy savings is achieved due to optimal control of the outdoor airflow rate.
Reliability
Designed to withstand hard environments.
IP55 sealed electrical component box
IP55 sealed component box protects electrical component from a cause of failure, that is the ingress of debris (lizards, bugs, sand, water).
The internal mounting plate is hinged, enabling easy maintenance of the PCB on the back.
Gecko Experiment on the Electrical Component Box
Individual electrical component boxes were used to conduct accelerated testing of gecko ingress, considered a frequent cause of failures in the market. An electrical component box was placed in an acrylic box along with 20 geckos, for 24-hour tests conducted over four days.

Enables operation in high outdoor temperature
Three refrigerant cooling circuits enable stable operation even in high outdoor temperatures by suppressing a temperature rise for the PCB mounted in the sealed electrical component box.
Expanded operation temperature range
The outdoor operation temperature range is now extended from 49 to 52°C. This enables reliable operation even under high temperature conditions and a wider choice of installation locations.
Keep rated cooling capacity in high outdoor
temperature up to 43°C*
Rated cooling capacity can be maintained even when outdoor temperature is up to 43°C*.
*Rated cooling capacity for 16-20 HP is up to 42°C.
IP55
IP55 is the degrees of dust and water protection for the electrical component box equipped on the product.
*IP55 is the protection degree of the wiring box as a single unit. The protection grade of outdoor unit is IP14 as well as conventional model.
Design Flexibility
Long piping length enhances design flexibility, enabling support for large buildings.
Long refrigerant piping
Simultaneous extension of height difference and equivalent length
Design flexibility is further improved by simultaneous extension of height difference, improved from 90 m to 110 m, and equivalent length (up to 190 m).
-
Height difference extension
Max. 110 mFor height differences exceeding 50 m with the outdoor unit above the indoor unit and 40 m with the outdoor unit below, the main piping liquid piping size must be increased.
The operating temperature range is up to 49˚C (Outdoor units above indoor units only).
The minimum connection capacity index of the indoor unit shall be 62.5 (7.1 kW) or more (Outdoor units above indoor units only). -
Equivalent length extension
Max. 190 mWhen the equivalent piping length from outdoor unit to indoor unit is 90 m or more, be sure to increase the size of the liquid and gas pipes of the main piping.
* In addition to increasing the size of the main pipe, there are other piping restrictions regarding height difference extension and equivalent length. Check the Installation Manual for details.
REFNET header downstream branching supported
Piping branch by REFNET joint is possible downstream of REFNET header.
The indoor unit arrangement can be more flexible.
Easy Installation
New structure improves installability.
Automatic refrigerant charge function
Simultaneous extension of height difference and equivalent length

Contribute to optimised operation efficiency, higher quality and easier installation.
Electrical component service window
Main PCB 7-segment LED and setting buttons can be accessed without removing the front panel. Workability has been highly improved for servicing and field settings.
Process visualization
(Test run only*)
In the new models, in addition to the actual step (t01 to t10), a progress rate (0% to 99%) is available as a guideline when making arrangements for on-site work.
* Effective when test run is carried out independently after manual refrigerant charging.
Improved refrigerant piping workability
By dividing piping and wiring holes to the left and right, piping and wiring work can be easily performed on site.
Comfort
Suppresses the nighttime operating sound to maintain the quiet environment.
Nighttime quiet operation function
The nighttime quiet operation function automatically suppresses the nighttime operating sound by reducing operation capacity to maintain the quiet environment of the neighborhood.
Three selectable modes are available depending on the required level.
- *1. Initial setting is 8 hours. Can be selected from 6, 8 and 10 hours.
- *2. Initial setting is 9 hours. Can be selected from 8, 9 and 10 hours.
- *3. In case of 6-12 HP outdoor unit.
Notes: This function is available in setting at site.
The operating sound in quiet operation mode is the actual value measured by our company.
The relationship of outdoor temperature (load) and time shown above is just an example.
Double backup operation functions
Unit backup & Compressor backup ensure continuous operation.

Engineering Support
Design assistance and sales proposal