Features
Connectable up to 9 indoor units
As many as 9 indoor units can be connected to a single outdoor unit, making the VRV IV S 5 ticks series a remarkably versatile system. Note: Total capacity index of connectable indoor units must be 50-130% of the capacity index of the outdoor unit.
Makes the long piping design possible
Specifications
| MODEL | RXMUQ4AVEG | RXMUQ5AVEG | RXMUQ6AVEG | ||
|---|---|---|---|---|---|
| Power supply | 1-phase, 220-230 V/220 V, 50/60 Hz | ||||
| Number of connectable indoor units | 6 | 8 | 9 | ||
| Cooling capacity | Btu/h | 38,200 | 47,800 | 54,600 | |
| kW | 11.2 | 14.0 | 16.0 | ||
| Power consumption (Outdoor unit)*¹ | kW | 1.98 | 2.52 | 2.96 | |
| Capacity control | % | 24-100 | |||
| Casing colour | Ivory white | ||||
| Compressor | Type | Hermetically sealed scroll type | |||
| Motor output × Number of units |
kW | 1.49 × 1 | 1.85 × 1 | 1.93 × 1 | |
| Airflow rate | m³/min | 140 | |||
| Dimensions (H × W × D) | mm | 1,430 × 940 × 320 | |||
| Machine weight | kg | 127 | |||
| Sound level | dB(A) | 52 | 53 | 55 | |
| Operation range | °CDB | -5 to 46 | |||
| Refrigerant | Type | R-410A | |||
| Charge | kg | 4.0 | |||
| Piping connections | Liquid | mm | ϕ9.5 (Flare) | ||
| Gas | mm | ϕ15.9 (Flare) | ϕ19.1 (Brazing) | ||
Notes: Specifications are based on the following conditions;
- Cooling: Indoor temp.: 27 ̊CDB, 19 ̊CWB, Outdoor temp.: 35 ̊CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
- Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode. units When there is concern for noise the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.
- Refrigerant charge is required.
Indoor units lineup
| Type | Model Name | 20 | 25 | 32 | 40 | 50 | 63 | 80 | 100 | 125 | 140 | |
| Capacity Range | 0.8 HP | 1 HP | 1.25 HP | 1.6 HP | 2 HP | 2.5 HP | 3.2 HP | 4 HP | 5 HP | 6 HP | ||
| Capacity Index | 20 | 25 | 32.25 | 40 | 50 | 62.5 | 80 | 100 | 125 | |||
| Ceiling Mounted Cassette | FXFSQ-AVM(G) |
|
||||||||||
| Slim Ceiling Mounted Duct (Standard Series) |
FXDQ-PDVE (with drain pump) |
![]() (700mm width type) |
||||||||||
| FXDQ-PDVET (without drain pump) |
||||||||||||
| FXDQ-NDVE (with drain pump) |
![]() (900/1, 100mm width type) |
|||||||||||
| FXDQ-NDVET (without drain pump) |
||||||||||||
| Middle Static Pressure Ceiling Mounted Duct | FXSQ-PAVE |
|
||||||||||
| Ceiling Mounted Duct | FXMQ-PAVE |
|
Refer to each indoor unit’s specification table in page 3-6.
Ceiling Mounted Cassette Type
FXFSQ-A
*Applicable when wired remote controller BRC1E63 is used.
Individual Airflow Direction Control*
Comfortable air conditioning for all room layouts and conditions
Airflow direction can be individually adjusted for each air discharge outlet to deliver optimal air distribution.
Circulation Airflow*
Configurations of Circulation Airflow
Cools the entire room to deliver comfort that never feels cold.
Specification
| MODEL | FXFSQ25AVMG | FXFSQ40AVMG | FXFSQ63AVM | FXFSQ100AVM | FXFSQ125AVM | FXFSQ140AVM | ||
| Power supply | 1-phase, 220-240 V/220-230 V, 50/60 Hz | |||||||
| Cooling capacity | Btu/h | 9,600 | 15,400 | 24,200 | 38,200 | 47,800 | 54,600 | |
| kW | 2.8 | 4.5 | 7.1 | 11.2 | 14.0 | 16.0 | ||
| Power consumption | kW | 0.056 | 0.061 | 0.164 | 0.170 | 0.194 | ||
| Casing | Galvanised steel plate | |||||||
| Airflow rate (H/HM/M/ML/L) |
m³/min | 21/20.5/19/14.5/11 | 21.5/20.5/19/14.5/11 | 23.5/21/20/16/13.5 | 33.5/30.5/27/23.5/21 | 34.5/31.5/28.5/25.5/23 | 35.5/32.5/29.5/26.5/23 | |
| cfm | 741/724/671/512/388 | 759/724/671/512/388 | 830/741/706/565/477 | 1,183/1,077/953/830/741 | 1,218/1,112/1,006/900/812 | 1,253/1,147/1,041/935/812 | ||
| Sound level (H/HM/M/ML/L) |
dB(A) | 37/35/34.5/29.5/27 | 37.5/35/34.5/29.5/27 | 38/36/35.5/31.5/28 | 44/41/38/35/33 | 45/42.5/39.5/37/35 | 46/43.5/40.5/38/35 | |
| Dimensions (H×W×D) | mm | 256×840×840 | 298×840×840 | |||||
| Machine weight | kg | 24 | 22 | 25 | 26 | |||
| Piping connections | Liquid (Flare) | kW | Φ6.4 | Φ9.5 | ||||
| Gas (Flare) | Φ12.7 | Φ15.9 | ||||||
| Drain | VP25 (External Dia, 32/Internal Dia, 25) | |||||||
Notes: Specifications are based on the following conditions;
- Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
- Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.(See Engineering Data Book for details.)
- Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Slim Ceiling Mounted Duct Type
(Standard Series)
FXDQ-PD / ND
Slim design, quietness and static pressure switching
- Only 700 mm in width and 23 kg in weight, hotel use! FXDQ20-32PD this model is suitable to install in limited spaces like drop-ceilings in hotels.
- Only 200 mm in height, this model can be installed in rooms with as little as 240 mm in height for the ceiling space between the drop-ceiling and ceiling slab.
- Control of the airflow rate can be selected from 3-step control and Auto. Auto airflow rate control can be selected with wired remote controller BRC1E63.
- Low operation sound level.
- External static pressure selectable by remote controller switching make this indoor unit a very comfortable and flexible model.
- FXDQ-PD and FXDQ-ND models are available in two types to suit different installation conditions.
FXDQ-PD/NDVE: with a drain pump (750 mm lift) as a standard accessory
FXDQ-PD/NDVET: without a drain pump
Specification
| MODEL | witd drain pump | FXDQ20PDVE | FXDQ25PDVE | FXDQ32PDVE | FXDQ40NDVE | FXDQ50NDVE | FXDQ63NDVE | |
| witdout drain pump | FXDQ20PDVET | FXDQ25PDVET | FXDQ32PDVET | FXDQ40NDVET | FXDQ50NDVET | FXDQ63NDVE | ||
| Power Supply | 1-phase, 220-240 V/220 V, 50/60 Hz | |||||||
| Cooling Supply | Btu/h | 7,500 | 9,600 | 12,300 | 15,400 | 19,100 | 24,200 | |
| kW | 2.2 | 2.8 | 3.6 | 4.5 | 5.6 | 7.1 | ||
|
Power consumption (FXDQ-PD/NDVE)*¹ |
0.086 | 0.089 | 0.160 | 0.165 | 0.181 | |||
|
Power consumption (FXDQ-PD/NDVET)*¹ |
0.067 | 0.070 | 0.147 | 0.152 | 0.168 | |||
| Casing | Galvanised steel plate | |||||||
| Airflow rate (HH/H/L) | m³/min | 8.0/7.2/6.4 | 10.5/9.5/8.5 | 12.5/11.0/10.0 | 16.5/14.5/13.0 | |||
| cfm | 282/254/226 | 371/335/300 | 441/388/353 | 583/512/459 | ||||
| External static pressure | Pa | 30-10 *² | 44-15 *² | |||||
| Sound level (HH/H/L)*¹*³ | dB(A) | 28/26/23 | 28/26/24 | 30/28/26 | 33/30/27 | 33/31/29 | ||
| Dimensions (H×W×D) | mm | 200×700×620 | 200×900×620 | 200×1,100×620 | ||||
| Machine Weight | kg | 23 | 27 | 28 | 31 | |||
| Piping connections | Liquid (Flare) | mm | Φ6.4 | Φ9.5 | ||||
| Gas (Flare) | Φ12.7 | Φ15.9 | ||||||
| Drain | VP20 (External Dia, 26/Internal Dia, 20) | |||||||
Notes: Specifications are based on the following conditions;
- Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
- Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.(See Engineering Data Book for details.)
- Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Middle Static Pressure Ceiling
Mounted Duct Type
FXSQ-PA
Middle external static pressure and slim design allow flexible installations
Installation flexibility
Slim design
With a height of only 245 mm, installation is possible even in buildings with narrow ceiling spaces.
Standard DC drain pump
DC drain pump is equipped as standard accessory with 850 mm lift.
Design flexibility
Adjustable external static pressure
Using a DC fan motor, the external static pressure can be controlled within a range of 30 Pa* to 150 Pa.
Comfortable airflow is achieved in accordance with conditions such as duct length.
*30 Pa–150 Pa for FXSQ20-40PAVE
50 Pa–150 Pa for FXSQ50-125PAVE
50 Pa–140 Pa for FXSQ140PAVE
Easy installation
Adjustable external static pressure
Airflow rate auto adjustment function
- During installation, even if the external static pressure changes due to a change in the duct route, the airflow can be automatically adjusted to within the unit’s external static pressure range.
- Airflow rate can be controlled using a remote controller during test operation. It is automatically adjusted to the range between approximately ±10% of the rated H tap airflow.
Design flexibility
Easy maintenance
Inspection and cleaning is facilitated by separating the drain pipe and inspection opening and by the drain pan maintenance check hole.
Specification
| MODEL | FXSQ20PAVE | FXSQ25PAVE | FXSQ32PAVE | FXSQ40PAVE | FXSQ50PAVE | FXSQ63PAVE | FXSQ80PAVE | FXSQ100PAVE | FXSQ125PAVE | FXSQ140PAVE | ||
| Power Supply | 1-phase, 220-240 V/220 V, 50/60 Hz | |||||||||||
| Cooling Supply |
Btu/h | 7,500 | 9,600 | 12,300 | 15,400 | 19,100 | 24,200 | 30,700 | 38,200 | 47,800 | 54,600 | |
| kW | 2.2 | 2.8 | 3.6 | 4.5 | 5.6 | 7.1 | 9.0 | 11.2 | 14.0 | 16.0 | ||
| Power Consumption |
mm | 0.058*¹ | 0.066*¹ | 0.101*¹ | 0.075*¹ | 0.106*¹ | 0.126*¹ | 0.151*¹ | 0.206*¹ | 0.222*¹ | ||
| Casing | Galvanised steel plate | |||||||||||
|
Airflow rate (HH/M/L) |
m³/min | 9/7.5/6.5 | 9.5/8/7 | 15/12.5/10.5 | 17/14.5/11.5 | 21/17.5/14.5 | 23/19.5/16 | 32/27/22.5 | 37/31.5/26 | 39/33.5/28 | ||
| cfm | 318/265/230 | 335/282/247 | 530/441/371 | 600/512/406 | 741/618/512 | 812/688/565 | 1,130/953/794 | 1,306/1,112/918 | 1,377/1,183/988 | |||
| External Static Pressure |
Pa | 30-150(50)*² | 50-150(50)*² | 50-140(50)*² | ||||||||
| Sound level (H/M/L) |
dB(A) | 33/30/28 | 34/32/30 | 36/33/30 | 34/32/29 | 36/32/29 | 37.5/34/30 | 39/35/32 | 42/38.5/35 | 43/40/36 | ||
| Dimensions (H×W×D) |
mm | 245×550×800 | 245×700×800 | 245×1,000×800 | 245×1,400×800 | 245×1,550×800 | ||||||
| Machine weight |
kg | 25 | 27 | 35 | 37 | 46 | 47 | 52 | ||||
| Piping connections |
Liquid (Flare) |
mm | Φ6.4 | Φ9.5 | ||||||||
| Gas (Flare) |
Φ12.7 | Φ15.9 | ||||||||||
| Drain | VP25 (External Dia, 32/Internal Dia, 25) | |||||||||||
Notes: Specifications are based on the following conditions;
- Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
- Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
- Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Ceiling Mounted Duct Type
FXMQ-PAVE
Using a DC fan motor, the external static pressure can be controlled within a range of 30 Pa* to 200 Pa*.
Middle and high static pressure allows for flexible duct design
-
Comfortable airflow is achieved in accordance with conditions such as duct length.
*30 Pa–100 Pa for FXMQ20PA-32PA
*30 Pa–160 Pa for FXMQ40PA
*50 Pa–200 Pa for FXMQ50PA-125PA
*50 Pa–140 Pa for FXMQ140PA - All models are only 300 mm in height and the weight of the FXMQ40-140PA has been reduced.
- Drain pump is equipped as standard accessory with 700 mm lift.
- Control of the airflow rate can be selected from 3-step control and Auto. Auto airflow rate control can be selected with wired remote controller BRC1E63.
- Low operation sound level
- Energy-efficient – DC fan motor is used to realise energy-saving operation.
- Easy installation – Airflow rate can be controlled using a remote controller during test operation. It is automatically adjusted to the range between approximately ±10% of the rated HH tap airflow for FXMQ20PA–125PA.
- Easy maintenance – Inspection and cleaning is facilitated by separating the drain pipe and inspection opening and by the drain pan maintenance check hole.
- An antibacterial treatment that uses silver ions has been applied to the drain pan, preventing the growth of slime, mould and bacteria that cause blockages and odours. (The lifespan of a silver ion cartridge depends on the usage environment, but should be changed once every two to three years.)
Specification
| MODEL | FXMQ20PAVE | FXMQ25PAVE | FXMQ32PAVE | FXMQ40PAVE | FXMQ50PAVE | FXMQ63PAVE | FXMQ80PAVE | FXMQ100PAVE | FXMQ125PAVE | FXMQ140PAVE | ||
| Power Supply | 1-phase, 220-240 V/220 V, 50/60 Hz | |||||||||||
| Cooling Supply |
Btu/h | 7,500 | 9,600 | 12,300 | 15,400 | 19,100 | 24,200 | 30,700 | 38,200 | 47,800 | 54,600 | |
| kW | 2.2 | 2.8 | 3.6 | 4.5 | 5.6 | 7.1 | 9.0 | 11.2 | 14.0 | 16.0 | ||
| Power Consumption |
mm | 0.056*¹ | 0.060*¹ | 0.151*¹ | 0.128*¹ | 0.138*¹ | 0.185*¹ | 0.215*¹ | 0.284*¹ | 0.405*¹ | ||
| Casing | Galvanised steel plate | |||||||||||
|
Airflow rate (HH/H/M/L) |
m³/min | 9/7.5/6.5 | 9.5/8/7 | 16/13/11 | 18/16.5/15 | 19.5/17.5/16 | 25/22.5/20 | 32/27/23 | 39/33/28 | 46/39/32 | ||
| cfm | 318/265/230 | 335/282/247 | 565/459/388 | 635/582/530 | 688/618/565 | 883/794/706 | 1,130/953/812 | 1,377/1,165/988 | 1,624/1,377/1,130 | |||
| External Static Pressure |
Pa | 30-100(50)*² | 30-160(100)*² | 50-200(100)*² | 50-140(100)*² | |||||||
| Sound level (H/M/L) |
dB(A) | 33/31/29 | 34/32/30 | 39/37/35 | 41/39/37 | 42/40/38 | 43/41/39 | 44/42/40 | 46/45/43 | |||
| Dimensions (H×W×D) |
mm | 300×550×700 | 300×700×700 | 300×1,000×700 | 300×1,400×700 | |||||||
| Machine weight |
kg | 25 | 27 | 35 | 45 | 46 | ||||||
| Piping connections |
Liquid (Flare) |
mm | Φ6.4 | Φ9.5 | ||||||||
| Gas (Flare) |
Φ12.7 | Φ15.9 | ||||||||||
| Drain | VP25 (External Dia, 32/Internal Dia, 25) | |||||||||||
Notes: Specifications are based on the following conditions;
- Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
- Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
- Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Decoration Panel Lineup
Option
Standard panel with sensing
BYCQ125EEF (Fresh White)
Standard panel
BYCQ125EAF (Fresh White)
Designer panel
BYCQ125EAPF (Fresh White)
Standard panel with sensing
BYCQ125EEK (Black)
Standard panel
BYCQ125EAK (Black)
Auto grille panel
BYCQ125EASF (Fresh White)
Connection condition of indoor units


External static pressure is changeable to set by the remote controller. This pressure means “High static pressure – Standard”.(Factory setting is 10 Pa for FXDQ-PD models and 15 Pa for FXDQ-ND models.)
The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).