Features

The energy-efficient system recovers waste heat as energy to heat hot water.

Waste heat from air conditioning (which usually released into the ambience) is recovered to heat water.

The Serpentine Heat Exchanger Unit recovers heat.

Increased energy efficiency of the outdoor unit

The waste heat from air conditioning is transferred to heat water.
This mechanism reduces the amount of heat processed by the outdoor unit, resulting in better operation efficiency.

Reducing short circuits

The temperature of exhaust heat from the outdoor unit is lower, minimising in ambient temperature increase. In the event of a short circuit, capacity reduction is minimised.

Innovative and reliable system

Example on usage of VRV IV Heat Recovery Hot Water System for residence

In a sample family model of 3 adults and 3 children, the waste heat generated by air conditioning is sufficient to supply hot water for everybody’s showers.

Water-heating load Tank capacity: 200 L
Boiling temperature: 25°C to 60°C (tap water)

Amount of hot water per person per time (standard): 50 L/shower (39°C) (water dispensed: 10 L/min.; shower time: 5 min./shower)
Amount of water required in tank to dispense 39°C hot water

VRV IV Heat Recovery Hot Water Controller
Features

Convertible Remote Controller
Main Remote Control & Sub Remote Controller are both convertible and interchangeable.

Anti-Bacteria
By default, this would be activated every Monday morning at 2am, heating storage water up to 60°C for 10 minutes.

Vacation Mode
This disable all other functions, except for anti-bacterial mode.

Auto Restart
When power supply is restored after a failure, the system would revert to the last operational function.

Safety-Error Code
If thermistors or communication line are faulty, as a safety precaution, operation of the electric heater is disabled.

VRV IV Heat Recovery Hot Water System overview

Schematic Diagram For Residential Application

Schematic Diagram For Commercial Application

Specifications

Outdoor Units

High-COP Type

MODEL RWHQ12THYM RWHQ14THYM RWHQ16THYM RWHQ18THYM RWHQ20THYM RWHQ22THYM RWHQ24THYM
Combination units RWHQ6TYM RWHQ6TYM RWHQ8TYM RWHQ6TYM RWHQ6TYM RWHQ6TYM RWHQ8TYM
RWHQ8TYM RWHQ8TYM RWHQ8TYM RWHQ6TYM RWHQ8TYM RWHQ8TYM RWHQ8TYM
RWHQ6TYM RWHQ8TYM RWHQ8TYM RWHQ8TYM
Power supply 3-phase 4-wire system, 380-415/380 V, 50/60 Hz
Cooling capacity kcal/h 27,500 33,000 38,500 41,300 46,800 52,300 57,800
Btu/h 109,000 131,000 153,000 164,000 186,000 207,000 229,000
kW 32.0 38.4 44.8 48.0 54.4 60.8 67.2
Power consumption kW 7.10 8.68 10.3 10.7 12.2 13.8 15.4
Capacity control % 10-100 10-100 10-100 7-100 7-100 7-100 7-100
Casing colour Ivory white (5Y7.5/1)
Compressor Type Hermetically Sealed Scroll Type
Motor output kW (2.4×1)+(2.4×1) (2.4×1)+(3.4×1) (3.4×1)+(3.4×1) (2.4×1)+(2.4×1)+(2.4×1) (2.4×1)+(2.4×1)+(3.4×1) (2.4×1)+(3.4×1)+(3.4×1) (3.4×1)+(3.4×1)+(3.4×1)
Airflow rate m³/min 119+119 119+157 157+157 119+119+119 119+119+157 119+157+157 157+157+157
Dimensions (H×W×D) mm (1,657×930×765)+(1,657×930×765) (1,657×930×765)+(1,657×930×765)+(1,657×930×765)
Machine weight kg 185+185 185+185+185
Sound level dB(A) 58 59 59 60 60 60 61
Operation range °CDB 15 to 49
Refrigerant Type R-410A
Charge kg 6.4+6.4 6.4+6.4 6.4+6.4 6.4+6.4+6.4 6.4+6.4+6.4 6.4+6.4+6.4 6.4+6.4+6.4
Piping connections
(Indoor unit)
Liquid mm φ12.7
(Brazing)
φ12.7
(Brazing)
φ12.7
(Brazing)
φ15.9
(Brazing)
φ15.9
(Brazing)
φ15.9
(Brazing)
φ15.9
(Brazing)
Gas mm φ28.6
(Brazing)
φ28.6
(Brazing)
φ28.6
(Brazing)
φ28.6
(Brazing)
φ28.6
(Brazing)
φ28.6
(Brazing)
φ34.9
(Brazing)
Piping connections
(Heat exchanger unit)
Inlet pipe mm φ19.1 (Brazing×2) φ19.1 (Brazing×3)
Outlet pipe mm φ19.1 (Brazing×2) φ19.1 (Brazing×3)

Note: Specifications are based on the following conditions;

•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB,
Equivalent piping length: 7.5 m, Level difference: 0 m.

•Sound level: Anechoic chamber conversion value, measured at a point
1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat
higher as a result of ambient conditions.

Standard Type

MODEL RWHQ6TYM RWHQ8TYM RWHQ10TYM RWHQ12TYM RWHQ14TYM RWHQ16TYM
Combination units
Power supply 3-phase 4-wire system, 380-415/380 V, 50/60 Hz
Cooling capacity kcal/h 13,800 19,300 24,100 28,800 34,400 38,700
Btu/h 54,600 76,400 95,500 114,000 136,000 154,000
kW 16.0 22.4 28.0 33.5 40.0 45.0
Power consumption kW 3.55 5.13 7.22 8.93 10.8 12.9
Capacity control % 20-100 20-100 16-100 15-100 11-100 10-100
Casing colour Ivory white (5Y7.5/1)
Compressor Type Hermetically Sealed Scroll Type
Motor output kW 2.4×1 3.4×1 4.1×1 5.2×1 (2.9×1)+(3.3×1) (3.6×1)+(3.7×1)
Airflow rate m³/min 119 157 165 178 233 233
Dimensions (H×W×D) mm 1,657×930×765 1,657×1,240×765
Machine weight kg 185 185 200 200 285 285
Sound level dB(A) 55 56 57 59 60 61
Operation range °CDB 15 to 49
Refrigerant Type R-410A
Charge kg 6.4 6.4 6.5 6.8 10.3 10.4
Piping connections
(Indoor unit)
Liquid mm φ9.5
(Brazing)
φ12.7
(Brazing)
Gas mm φ19.1
(Brazing)
φ22.2
(Brazing)
φ28.6
(Brazing)
Piping connections
(Heat exchanger unit)
Inlet pipe mm φ19.1 (Brazing)
Outlet pipe mm φ19.1 (Brazing)

Note: Specifications are based on the following conditions;

•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB,
Equivalent piping length: 7.5 m, Level difference: 0 m.

•Sound level: Anechoic chamber conversion value, measured at a point
1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat
higher as a result of ambient conditions.

Space Saving Type

MODEL RWHQ18TYM RWHQ20TYM RWHQ22TSYM RWHQ24TSYM
Combination units RWHQ10TYM RWHQ12TYM
RWHQ12TYM RWHQ12TYM
Power supply 3-phase 4-wire system, 380-415/380 V, 50/60 Hz
Cooling capacity kcal/h 43,000 48,200 52,900 57,600
Btu/h 171,000 191,000 210,000 229,000
kW 50.0 56.0 61.5 67.0
Power consumption kW 15.3 17.9 16.2 17.9
Capacity control % 10-100 8-100 8-100 8-100
Casing colour Ivory white (5Y7.5/1)
Compressor Type Hermetically Sealed Scroll Type
Motor output kW (4.4X1)+(4.0X1) (4.6X1)+(5.5X1) (4.1X1)+(5.2X1) (5.2X1)+(5.2X1)
Airflow rate m³/min 233 268 165+178 178+178
Dimensions (H×W×D) mm 1,657×1,240×765 1,657×1,240×765 (1,657×930×765)+(1,657×930×765) (1,657×930×765)+(1,657×930×765)
Machine weight kg 285 320 200+200 200+200
Sound level dB(A) 62 65 61 62
Operation range °CDB 15 to 49
Refrigerant Type R-410A
Charge kg 10.5 11.8 6.5+6.8 6.8+6.8
Piping connections
(Indoor unit)
Liquid mm φ15.9
(Brazing)
φ15.9
(Brazing)
φ15.9
(Brazing)
φ15.9
(Brazing)
Gas mm φ28.6
(Brazing)
φ28.6
(Brazing)
φ28.6
(Brazing)
φ34.9
(Brazing)
Piping connections
(Heat exchanger unit)
Inlet pipe mm φ19.1 (Brazing) φ19.1 (Brazing×2)
Outlet pipe mm φ19.1 (Brazing) φ19.1 (Brazing×2)

Note: Specifications are based on the following conditions;

•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB,
Equivalent piping length: 7.5 m, Level difference: 0 m.

•Sound level: Anechoic chamber conversion value, measured at a point
1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat
higher as a result of ambient conditions.

HWHQ30A

New Model Name
(RWHQ-TYM, WHHQ30A)
Single Heat Exchanger Unit
RWHQ6TYM
+HWHQ30A
RWHQ8TYM
+HWHQ30A
RWHQ10TYM
+HWHQ30A
RWHQ12TYM
+HWHQ30A
RWHQ14TYM
+HWHQ30A
RWHQ16TYM
+HWHQ30A
RWHQ18TYM
+HWHQ30A
RWHQ20TYM
+HWHQ30A

Rated inlet temperature

°C
40

Rated water flow

L/min
10

Range of inlet temperature

°C
20-65

Range of water flow

L/min
5-20

Rated Hot-water capacity1

kW
3.2 3.3 3.3 3.5 3.7 4.0 4.2 4.4

Machine weight

kg
27

Diameter of Refrigerant pipe (Gas)

mm
φ19.1 (Braze)

Diameter of Refrigerant pipe (Liquid)

mm
φ19.1 (Braze)

Diameter of water pipe (Inlet)

mm
φ25.4 (Screw)

Diameter of water pipe (Outlet)

mm
φ25.4 (Screw)

Piping length (max)

m
2 (5)

Design pressure (Water side)

MPa
0.5

Loss of Head2

m
0.2

Casing colour
Ivory white (5Y7.5/1)

Dimensions (H×W×D)

mm
446 × 306 × 765

Notes: It is necessary to satisfy the water standard of Daikin for the water that is used.
In the case that the water standard is not satisfied, special measures are required.
Please contact your local sales office for details.

*1: [Cooling] Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB,
Inlet water temperature 40°C, Water flow 10 L/min,
Indoor load 100%, Outdoor-Heat Exchanger Unit 2m.

*2: Water flow 10 L/min.

GET STARTED