• Warranty Registration | View Warranty
  • FAQ

    Benefits

    Benefits of system replacement

    Quick, Quality and Economical

    Reuse

    Simple use of existing refrigerant piping.

    In the past, special equipment and work was needed to clean pipes when using existing piping, but this is no longer required. A new function automatically deals with contamination inside piping during refrigerant charging, eliminating the work involved in cleaning.

    Even applicable for non-DAIKIN systems!
    The Daikin low-cost upgrade solution


    Automatic

    Refrigerant charging, cleaning and test operation done with just a single switch.

    The unique automatic refrigerant charge eliminates the need to calculate refrigerant volume, simplifying the installation process. Not knowing the exact piping lengths because of changes or mistakes in case you didn't do the original installation or replacing a competitor installation no longer poses a problem. Furthermore, there is no need to clean inside piping as this is handled automatically by the VRV IV Q unit.


    Time saving

    Enables smooth replacement of air conditioning with less effect on operations and users in the building.


    Cost saving

    Work costs for pipe removal, installation and insulation account for much of the total cost. By the reuse of existing piping, 35% of cost down can be realized compared to installing new pipes.

     


    ReLated services

    Design flexibility

    Significantly more compact outdoor unit enables the effective use of limited space!

    Compact design enables the effective use of space taken up by existing machinery

    High external static pressure 78.4 Pa

    Small and light, significantly reducing constraints during carry-in

     


    Can be carried on a cart

    Can be carried on a cart

     


    System flexibility

    An increased number of connectable indoor units in a single system

    More indoor units can be connected in a single system, enabling consolidation of existing piping!

    The number of connectable indoor units has been drastically increased from 30 to 64.


    Enables increased capacity

    System can be upgraded using existing piping

    VRV IV Q series for replacement use enables the system capacity to be increased without changing the refrigerant piping. For example, it is possible to install a 16 HP VRV IV Q series using the refrigerant piping of an 10 HP R-22 system.


    For reuse of existing refrigerant piping, it is possible to use piping or branched piping capable of handling 3.3 MPa or more.
    Heat insulation is necessary for liquid piping and gas piping.

     


    Enhanced Lineup

    2 types up to 48 HP

    With its enhanced lineup of 2 types and Standard and Space saving types, VRV IV Q series outdoor units offer a high capacity up to 48 HP to meet an ever wider variety of needs.

     


    Compact & Light Weight Design

    New Space Saving type with refined design

    As a leading global innovator, Daikin advanced from the conventional 2 module combination to a single module for 18 and 20 HP models. This allows the installation area to reduce by 33% as compared to the previous models.

     


    Energy Saving

    Higher Coefficient of Performance (COP)

    COP at 100% operation load

    VRV IV Q series delivers highly efficient performance, contributing to high energy savings.


    COP for 10 HP

    Improved efficiency during long operation under low load


    Features

    VRT-Variable Refrigerant Temperature

    State-of-the-art energy saving technology for VRV system

    Customise your VRV system for optimal annual efficiency

    The new VRV IV Q series now features VRT technology. VRT automatically adjusts refrigerant temperature to individual building and climate requirement, thus further improving annual energy efficiency and maintaining comfort. With this excellent technology, running costs are reduced.


    How is energy reduced?

    During cooling, the refrigerant evaporating temperature (Te) is raised to minimise the difference with the condensing temperature. Compressors work less, and this reduces power consumption.


    Typical changes in evaporating temperature and COP depending on changing indoor load



    New system, saving more energy

    Basic mode is selected to maintain optimal comfort.
    VRT is selected to save energy and prevent excessive cooling.


     

    VRT offers quicker cool down to shorten uncomfortable pull down time.

    Powerful Mode
    • Can boost capacity above 100% if needed.
      The refrigerant temperature can go lower in cooling than the set minimum.
    • Gives priority to very fast reaction speed.
      The refrigerant temperature goes down fast to keep the room setpoint stable.
    Quick Mode
    • Gives priority to fast reaction speed.
      The refrigerant temperature goes down fast to keep the room setpoint stable.
    Mild Mode
    • Gives priority to efficiency.
      The refrigerant temperature goes down gradually giving priority to the efficiency of the system instead of the reaction speed.

    Recommended for use in these situations
    • Cooling only regions having differences in daily temperature.
    • VRT is particularly effective at night when temperatures are low.


    Advanced Technologies Achieve

    New technology that enables use of existing piping

    New tested contamination collection meth
    A new method collects contamination from existing piping, eliminating compressors and electric valves malfunction.

    Acid

    An acid neutraliser agent is added to disable acids (chlorine ions), which cause corrosion.

    Impurities

    A generously sized filter is provided inside the refrigerant circuit which traps impurities.

    Iron powder

    A magnet is installed inside the accumulator where liquid refrigerant accumulates. The magnet attracts iron powder to keep the system clean.

    Large capacity all DC inverter compressor in compact casing

    Large capacity all DC inverter compressor using high tension strength material, realise 12 HP compressor using 8 HP casing.


    Outer Rotor DC Motor (ODM)

    Only Daikin adapted ODM with feature of stable rotation and volumetric efficiency

    Advantages of ODM

    Thanks to large diameter of the rotor,

    • Large torque with same electromagnetic force
    • Stable rotation in all range, and can be operated with small number of rotations


    Highly integrated heat exchanger

    Improve performance by increasing heat exchanger area while maintaining the same installation space.


     


    Excellent Performance

    Various advanced control main PC board

    SMT* mackaging technology
    • SMT packaging technology adopted by the whole computer control panel improves the anti-clutter performance.
    • Protects your compter boards from the adverse effect of sandy and humid weather.
    *SMT: Surface mounted technology

    Refrigerant cooling technology, ensures stability of PCB temperature



    Improve reliability at high ambient temperature
    It is possible to cool the inverter power module stability even at high ambient temperature.
    This helps to keep air-conditioning capacity and also reduces failure rate.

    Range

    Outdoor Unit Lineup

    Enhanced lineup to 2 types

    • With its enhanced lineup of 2 types and Standard and Space Saving types, VRV IV Q series outdoor units offer a high capacity up to 48 HP to meet an ever wider variety of needs.
    • The single outdoor unit has only 2 different shapes and dimensions, not only simplifying the design process, but also bringing the system flexibility to a new level.
    • With the outdoor unit capacity increased in increment of 2 HP, customers' needs can be precisely met.
    • Outdoor units with anti-corrosion specifications (-E type on request) are designed specifically for use in areas which are subject to salt damage and atmospheric pollution.
    Standard Type

    Space Saving Type


     


    Indoor Unit Lineup

    Variety of indoor unit

     


    Guidelines for reuse of existing refrigerant piping

    Piping limits for reuse of existing piping

    Reusability of existing piping for VRV IV Q series


    Outdoor Unit Combinations

    Standard Type

    Space Saving Type

    Controller

    Individual Control Systems for VRV Indoor Units

    Navigation Remote Controller (Wired remote controller) (Option)

    Simple operation

    Energy Saving

    Convenience

    Comfort

    Wireless remote controller (Option)

    Simplified remote controller (Option)

    Integrated Building Monitoring System


    Advanced Control Systems for VRV Indoor Units

    One touch selection enables flexible control of equipment in a building.

    For Energy Saving & Comfort

    intelligent Touch Manager maximises the advantages of VRV features

    intelligent Touch Manager is an advanced multi-zone controller that provides the most cost-effective way to control and monitor the Daikin VRV system.
    The 10.4" LCD touch screen is easy to use with three different screen views to include the floor plan layout view, icon view and list view and menus for system configurations.
    It is also easy to use with standardized remote Web Access from your PC.
    It can manage a total of 650 management points consisting of up to 512 Daikin indoor unit groups (up to 1024 indoor units) along with building equipment control / monitoring with Digital Inputs / Output (Di/Dio), Analog Inputs / Output (Ai/Ao) and Pulse input (Pi) optional devices.

    Specifications

    Outdoor Units
    Standard Type

    Space Saving Type

    Energy Efficient

    Get updates on latest news/promotions. Subscribe Now

    ×